在建設(shè)活動(dòng)板房之前,活動(dòng)板房的布局是非常重要的。如果前期布局做的不好,會(huì)對(duì)使用產(chǎn)生很大的影響,如漏水等。
濟(jì)南活動(dòng)板房廠家為總結(jié)了一些活動(dòng)的布置,董事會(huì)會(huì)議室的注意事項(xiàng)。
Before the construction of activity board house, the layout of activity board house is very important. If the previous layout is not well done, it will have a great impact on the use, such as water leakage. In order to summarize the arrangement of some activities and the precautions of the board of directors' meeting room, Jinan activity board house manufacturer made a summary.
1.所附墻板布局正確,表面平整;預(yù)埋墻板安裝應(yīng)平整,上下搭接處采用舌槽連接,外板向下搭接,搭接長(zhǎng)度不小于15mm。
1. The layout of the attached wallboard is correct and the surface is flat; the installation of the embedded wallboard shall be flat, the upper and lower overlaps shall be connected by tongue and groove, the outer board shall be overlapped downward, and the overlapping length shall not be less than 15mm.
2.移動(dòng)機(jī)房的電路采用PVC管(槽)制作,應(yīng)用明快,接線整齊美觀;電氣配置符合設(shè)計(jì)要求;無(wú)絕緣老化線,使用壽命長(zhǎng)。
2. The circuit of the mobile machine room is made of PVC pipe (slot), which is bright in application, neat and beautiful in wiring; the electrical configuration meets the design requirements; there is no insulation aging line, and the service life is long.
3.防腐:鋼構(gòu)件應(yīng)油漆完好,不生銹,外露螺栓應(yīng)妥善保護(hù);在強(qiáng)腐蝕性環(huán)境下的防腐措施符合設(shè)計(jì)要求;移動(dòng)式房屋周?chē)鷳?yīng)排水暢通,無(wú)積水,不得堆放雜物。
3. Anti corrosion: the steel members shall be painted in good condition without rust, and the exposed bolts shall be properly protected; the anti-corrosion measures under the strong corrosive environment shall meet the design requirements; the surrounding of the mobile house shall be free of water and sundries.
4.防雷:防雷地面設(shè)置符合設(shè)計(jì)和規(guī)范要求;接地電阻測(cè)試合格。
4. Lightning protection: the lightning protection ground shall meet the design and specification requirements; the grounding resistance test shall be qualified.
5.移動(dòng)式房屋面板安裝應(yīng)平穩(wěn),檐口平直,板重疊方向正確一致。
5. The panel installation of mobile house shall be stable, the cornice shall be straight, and the overlapping direction of the panel shall be correct and consistent.
6.防火:消防間距應(yīng)滿足設(shè)計(jì)和規(guī)范要求,消防通道應(yīng)暢通;消火栓、滅火器配置符合設(shè)計(jì)要求,布局合理。廚房火災(zāi)現(xiàn)場(chǎng)應(yīng)采取有效的防火保溫措施;金屬夾層板表面含氧量指數(shù)不低于32,木地板等可燃材料應(yīng)做防火處理。
6. Fire prevention: the fire fighting distance shall meet the design and specification requirements, and the fire fighting channel shall be unblocked; the configuration of fire hydrant and fire extinguisher shall meet the design requirements, and the layout shall be reasonable. Effective fire prevention and insulation measures shall be taken at the site of kitchen fire; the oxygen content index on the surface of metal sandwich panel shall not be less than 32, and fire prevention treatment shall be carried out for combustible materials such as wood floor.
7.活動(dòng)室圍護(hù)板(屋面板和墻板)應(yīng)無(wú)明顯變形、損壞;固定螺栓、防水墊片、金屬墊片、尼龍?zhí)坠艿三R全,連接可靠;密封膠完整有效。
7. The enclosure board (roof panel and wall panel) of the activity room shall be free from obvious deformation and damage; the fixed bolt, waterproof gasket, metal gasket, nylon sleeve, etc. shall be complete and connected reliably; the sealant shall be complete and effective.
以上是濟(jì)南活動(dòng)板房廠家為大家介紹的相關(guān)內(nèi)容,想要了解更多內(nèi)容,歡迎訪問(wèn)網(wǎng)站:http://
The above is the relevant content introduced by Jinan activity board house manufacturer. If you want to know more, please visit the website: http://